Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
J Chromatogr A ; 1641: 461984, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33611121

RESUMO

The in-situ synthesis and application of nanocubic Co3O4-coated graphene oxide (Co3O4@ GO) was introduced for the first time to present a cost-effective, stable and convenient operation and a simple device for hollow fiber solid-phase microextraction (HF-SPME) of four selected nonsteroidal anti-inflammatory drugs (NSAIDs) including diclofenac, mefenamic acid, ibuprofen and indomethacin. The extracted analytes were desorbed by an appropriate organic solvent and analyzed via high-performance liquid chromatography-ultraviolet detection (HPLC-UV). The prepared sorbent was approved using different characterization methods such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The variables effective on the Co3O4@GO-HF-SPME method including extraction time, desorption time, desorption solvent volume, sample pH, stirring rate and ionic strength were screened via Plackett-Burman design and then optimized by Box-Behnken design. Under optimal condition, the calibration curves were linear within the range of 1.0-200.0 µg L-1 of analyte concentration with detection limits of 0.18-1.1 µg L-1 and the relative standard deviations less than 10.1%. The limits of quantification (LOQs) were in the range of 0.60-3.67 µg L-1. Matrix effect was not observed with this method; therefore, standard addition is not necessary for quantification of target compounds. The enrichment factors were obtained in the range of 49-68. The relative recoveries of the urine sample analysis were calculated in the range of 93-102%. Finally, the presented method exhibited good sensitivity, excellent repeatability, high reusability and acceptable precision, which will be a promising method to analyze various nonsteroidal anti-inflammatory drugs in urine samples.


Assuntos
Anti-Inflamatórios não Esteroides/urina , Cobalto/química , Grafite/química , Nanocompostos/química , Óxidos/química , Microextração em Fase Sólida/métodos , Raios Ultravioleta , Adulto , Cromatografia Líquida de Alta Pressão , Diclofenaco/urina , Feminino , Humanos , Ibuprofeno/urina , Limite de Detecção , Masculino , Ácido Mefenâmico/urina
2.
Molecules ; 25(22)2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33182534

RESUMO

The rapid sensing of drug compounds has traditionally relied on antibodies, enzymes and electrochemical reactions. These technologies can frequently produce false positives/negatives and require specific conditions to operate. Akin to antibodies, molecularly imprinted polymers (MIPs) are a more robust synthetic alternative with the ability to bind a target molecule with an affinity comparable to that of its natural counterparts. With this in mind, the research presented in this article introduces a facile MIP-based dye displacement assay for the detection of (±) amphetamine in urine. The selective nature of MIPs coupled with a displaceable dye enables the resulting low-cost assay to rapidly produce a clear visual confirmation of a target's presence, offering huge commercial potential. The following manuscript characterizes the proposed assay, drawing attention to various facets of the sensor design and optimization. To this end, synthesis of a MIP tailored towards amphetamine is described, scrutinizing the composition and selectivity (ibuprofen, naproxen, 2-methoxphenidine, quetiapine) of the reported synthetic receptor. Dye selection for the development of the displacement assay follows, proceeded by optimization of the displacement process by investigating the time taken and the amount of MIP powder required for optimum displacement. An optimized dose-response curve is then presented, introducing (±) amphetamine hydrochloride (0.01-1 mg mL-1) to the engineered sensor and determining the limit of detection (LoD). The research culminates in the assay being used for the analysis of spiked urine samples (amphetamine, ibuprofen, naproxen, 2-methoxphenidine, quetiapine, bupropion, pheniramine, bromopheniramine) and evaluating its potential as a low-cost, rapid and selective method of analysis.


Assuntos
Anfetaminas/urina , Corantes/química , Polímeros Molecularmente Impressos , Polímeros/química , Detecção do Abuso de Substâncias/métodos , Urina/química , Anfetamina/urina , Bromofeniramina/urina , Bupropiona/urina , Relação Dose-Resposta a Droga , Técnicas Eletroquímicas , Reações Falso-Positivas , Humanos , Ibuprofeno/urina , Limite de Detecção , Impressão Molecular , Naproxeno/urina , Feniramina/urina , Piperidinas/urina , Pós , Fumarato de Quetiapina/urina
3.
Scand J Med Sci Sports ; 30(10): 1888-1895, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32585737

RESUMO

OBJECTIVES: To study the effects of running with/without the use of pain killers on urinary neutrophil gelatinase-associated lipocalin (uNGAL) and other parameters of kidney function in recreational runners. METHODS: Participants of the 10- and 21.1-km Weir Venloop race were enrolled and their urine samples collected before and after the run. Urine dipstick and other conventional tests used to assess kidney function were performed. The presence of ibuprofen, diclofenac, naproxen, and/or paracetamol was assessed by LC-MS/MS. uNGAL was measured with a two-step chemiluminescent immunoassay. RESULTS: NSAIDs/analgesics were detected in urine of 5 (14.4%) 10-km runners and 13 (28.9%) 21.1-km runners. Only half-marathon participants showed significant increases in uNGAL (pre: 11.7 [7.1-34.3] ng/mL; post: 33.4 [17.4-50.4] ng/mL; P = .0038). There was a significant effect of NSAID/analgesic use on uNGAL increase (F2, 76  = 4.210, P = .004). Post hoc tests revealed that uNGAL increased significantly in runners who tested positive for ibuprofen/naproxen compared to runners who did not use any medications (P = .045) or those who tested positive for paracetamol (P = .033). Running distance had a significant influence on the increase in uNGAL (F1, 53  = 4.741, P < .05), specific gravity (F1, 60  = 9.231, P < .01), urinary creatinine (F1, 61  = 10.574, P < .01), albumin (F1, 59  = 4.888, P < .05), and development of hematuria (χ2 (4) = 18.44, P = .001). CONCLUSIONS: Running distance and use of ibuprofen/naproxen were identified as risk factors for uNGAL increase in recreational runners.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Lipocalina-2/urina , Corrida/fisiologia , Acetaminofen/farmacologia , Acetaminofen/urina , Adulto , Análise de Variância , Anti-Inflamatórios não Esteroides/urina , Diclofenaco/farmacologia , Diclofenaco/urina , Feminino , Humanos , Ibuprofeno/farmacologia , Ibuprofeno/urina , Rim/fisiologia , Medições Luminescentes , Masculino , Pessoa de Meia-Idade , Naproxeno/farmacologia , Naproxeno/urina , Método Simples-Cego
4.
Artigo em Inglês | MEDLINE | ID: mdl-32248046

RESUMO

The present study is the first report of in-situ growth and application of nanorods-flower like Co3O4 nanosorbent coated on the anodized aluminum substrate for thin film microextraction (TFME) approach. The flower like Co3O4 was successfully fabricated by conversion of Co-Al layered double hydroxide (LDH) precursor to Co3O4 using the simple calcinations process. The cheap and available aluminum foil was electrochemically anodized and used as a porous substrate. Response surface methodology (RSM) was explored for optimization step. Different acidic drugs, including: paracetamol, ibuprofen, aspirin and diclofenac were extracted from biological fluids in order to investigate the capability of the prepared sorbent. The extracted analytes were then analyzed using high performance liquid chromatography-ultraviolet detection (HPLC-UV). Under the optimized conditions, the limits of detection were between 0.2 and 1.7 µg L-1 in different selected matrices. The obtained limits of quantification were also calculated to be between 0.8 and 5.1 µg L-1 in the selected matrices. In addition the enrichment factors were also in the range of 105-169. Batch-to-batch reproducibility at 100 µg L-1 concentration level was also evaluated to be lower than 5.2% (n = 3). Finally, the method was successfully used for analysis of these compounds in the biological fluids.


Assuntos
Ácidos/urina , Alumínio/química , Cobalto/química , Nanotubos/química , Óxidos/química , Acetaminofen/urina , Adsorção , Adulto , Aspirina/urina , Cromatografia Líquida de Alta Pressão , Diclofenaco/urina , Técnicas Eletroquímicas , Eletrodos , Feminino , Humanos , Hidróxidos/química , Ibuprofeno/urina , Limite de Detecção , Masculino , Reprodutibilidade dos Testes , Microextração em Fase Sólida , Propriedades de Superfície
5.
Mikrochim Acta ; 186(12): 759, 2019 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-31712934

RESUMO

A (glycidyl methacrylate)-co-(ethylene glycol dimethacrylate) polymer (poly(GMA-co-EDMA)) was functionalized with metal-organic frameworks (MOF) and used as a sorbent for solid-phase extraction (SPE). The polymeric sorbent was prepared in-situ by photopolymerization in a previously wall-modified spin column, and then modified with an amino-modified MOF of type NH2-MIL-101(Cr). The sorbents were used for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs) from human urine samples. The sorbent was compared with the parent monolith and embedded approach, where the MOF particles are admixed in the polymerization mixture before the in-situ polymerization in the modified spin column. SPE is performed by percolating the sample solutions in a centrifuge, which streamlines the SPE steps. The hybrid composites were characterized by scanning electron microscopy and nitrogen intrusion porosimetry. Three NSAIDs (ketoprofen, flurbiprofen, and ibuprofen) were tested. They were eluted from the sorbent with acidified water-acetonitrile mixtures and subsequently analyzed by reversed-phase HPLC with UV detection. The detection limits varied in the range from 0.1 to 7 µg·L-1, and the precisions (relative standard deviation) were <14% in all the cases. The recoveries were between 71.0 and 78.0% in spiked urine samples. Graphical abstractA hybrid monolith modified with amino-modified MOF [named NH2-MIL-101(Cr)] in wall-modified spin columns was prepared. The resulting micro-extraction device was applied to the extraction and preconcentration of non-steroidal anti-inflammatory drugs.


Assuntos
Anti-Inflamatórios não Esteroides/isolamento & purificação , Flurbiprofeno/isolamento & purificação , Ibuprofeno/isolamento & purificação , Cetoprofeno/isolamento & purificação , Estruturas Metalorgânicas/química , Microextração em Fase Sólida/métodos , Adsorção , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/urina , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Flurbiprofeno/química , Flurbiprofeno/urina , Humanos , Ibuprofeno/química , Ibuprofeno/urina , Cetoprofeno/química , Cetoprofeno/urina , Limite de Detecção , Metilmetacrilatos/química
6.
J Pharm Biomed Anal ; 174: 509-517, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31238298

RESUMO

Switchable-hydrophilicity solvent liquid-liquid microextraction was used prior to high-performance liquid chromatography with diode-array detector (HPLC-DAD) for the determination of four non-steroidal anti-inflammatory drugs [i.e., ketoprofen, etodolac, flurbiprofen and ibuprofen] in human urine, saliva and milk. Optimum extraction conditions were as follows: 500 µL switched-on N,N-dimethylcyclohexylamine as the extraction solvent, 9.5 mL of the aqueous phase, 500 µL 20 M sodium hydroxide as a switching-off trigger, and within 30 s extraction time. A portion of the final extract was directly injected into HPLC. Under optimized extraction and chromatographic conditions, limits of detection ranged between 0.04 and 0.18 µg mL-1 in all matrices analyzed. Good linearity with coefficients of determination (R2) ranging between 0.9955 and 0.9998, and percentage relative standard deviations (%RSD) of 0.9-7.7% were obtained. The proposed method was efficiently used for the extraction of the analytes in the biological fluids with percentage relative recoveries (%RR) ranging between 95.7 and 109.2%.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/urina , Cromatografia Líquida de Alta Pressão , Microextração em Fase Líquida , Leite Humano/química , Saliva/química , Centrifugação , Etodolac/urina , Flurbiprofeno/urina , Humanos , Interações Hidrofóbicas e Hidrofílicas , Ibuprofeno/urina , Cetoprofeno/urina , Modelos Lineares , Compostos Orgânicos , Reprodutibilidade dos Testes , Hidróxido de Sódio/química , Solventes/química
7.
J Chromatogr A ; 1602: 107-116, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31182304

RESUMO

Polystyrene is one of the best candidates as the extracting medium due to its high stability in different media and acceptable extraction capability. However, the hydrophobic nature and low wettability of polystyrene limits its application to non-polar analytes. To resolve this limitation, in this project, amine groups were chemically attached to the surface of magnetic polystyrene. The resulting hydrophilic magnetic particles were expected to be capable of extracting both polar and non-polar analytes. Non-steroidal anti-inflammatory drugs (NSAIDs) were chosen for testing the applicability of modified magnetic polystyrene according to the importance of their analysis and also their wide polarity range. Major parameters associated with the extraction procedure were optimized using central composite design (CCD) method and pH 3, extraction time of 15 min, desorption volume of 350 µL and desorption time of 4 min were chosen as optimized values. Under these conditions, figures of merit were calculated including: linear dynamic range (0.5-1000 µg L-1), linear equation and limits of detection (0.1-3 µg L-1). To investigate the method precision, inter-day, intra-day and synthesis-to-synthesis relative standard deviation (RSD) were studied (<12%). All studies were conducted using blank urine samples spiked with aspirin, salicylic acid, ibuprofen, diclofenac and mefenamic acid. Naproxen was chosen as the internal standard and high-performance liquid chromatography-UV-Vis (HPLC-UV) was employed for the subsequent determination after extraction. To evaluate the applicability of the method for real sample analysis, urine samples from patients under treatment were analyzed and acceptable results were obtained. The aminated magnetic polystyrene revealed superior extraction efficiency, much higher than polystyrene before functionalization. In addition, hospital wastewater sample was tested and acceptable extraction efficiencies were obtained.


Assuntos
Aminas/química , Magnetismo , Preparações Farmacêuticas/isolamento & purificação , Preparações Farmacêuticas/urina , Poliestirenos/química , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/urina , Diclofenaco/química , Diclofenaco/urina , Humanos , Ibuprofeno/química , Ibuprofeno/urina , Limite de Detecção , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Águas Residuárias/química
8.
Talanta ; 201: 496-502, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31122456

RESUMO

According to the molecular properties of non-steroidal anti-inflammatory drugs (NSADs), a new adsorbent for magnetic solid phase extraction (MSPE) was designed and synthesized. Triethyl-(4-vinylbenzyl)aminium chloride and 4-vinylbenzeneboronic acid were utilized as dual functional monomers to copolymerize with divinylbenzene on the surface of pre-modified Fe3O4 nanoparticles. The prepared magnetic adsorbent (Fe3O4@TCVA) was characterized by elemental analysis, Fourier transform infrared, scanning electron microscopy, transmission electron microscopy and vibrating sample magnetometer. Due to the abundant boronic acid, quaternary amine and phenyl groups, the Fe3O4@TCVA displayed satisfactory extraction performance for target NSADs (diclofenac acid, ibuprofen and mefenamic acid) by means of B-N coordination, anion-exchange, π-π and hydrophobic interactions. Under the optimized conditions, the Fe3O4@TCVA/MSPE was combined with high-performance liquid chromatography with diode array detection (HPLC-DAD) to sensitively analyze NSADs in water and human urine samples. Results indicated that the limits of detection for water and urine samples were in the ranges of 0.014-0.031 µg/L and 0.029-0.11 µg/L, respectively. The relative standard deviations for the intra-day and inter-day assay variability were below 10%. The applicability of the proposed Fe3O4@TCVA/MSPE-HPLC-DAD method was demonstrated by the successful extraction and quantification of trace levels of NSADs in real water and human urine samples. Satisfactory spiked recovery and reproducibility were achieved.


Assuntos
Anti-Inflamatórios não Esteroides/urina , Diclofenaco/urina , Ibuprofeno/urina , Ácido Mefenâmico/urina , Extração em Fase Sólida/métodos , Compostos de Vinila/química , Adsorção , Água Potável/análise , Humanos , Lagos/análise , Limite de Detecção , Nanopartículas de Magnetita/química , Polimerização , Polivinil/síntese química , Polivinil/química , Reprodutibilidade dos Testes , Cloreto de Sódio/química , Águas Residuárias/análise , Poluentes Químicos da Água/análise
9.
J Sep Sci ; 41(20): 3881-3891, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30101517

RESUMO

Ibuprofen is widely used in human and veterinary medicine for the treatment of chronic pain as well as rheumatic and musculoskeletal disorders. However, the analgesic and anti-inflammatory properties of Ibuprofen have contributed to frequent drug abuse in equestrian sports. A sensitive and rapid gas chromatography with tandem mass spectrometry based method with a simple liquid-liquid extraction and derivatization requiring 200 µL volume of sample and 2 mL of extraction solvent for the simultaneous determination of ibuprofen and its metabolites was developed. The proposed procedure was optimized and validated according to the principles for bioanalytical methods. The assay achieved satisfactory validation parameters, namely, recovery (92.2-105%), interday accuracy (92.5-106%), and precision (0.3-4.4%) for all investigated compounds as well as limits of quantification of 50 ng/mL for ibuprofen, 2-hydroxyibuprofen, and carboxyibuprofen, 25 ng/mL for 1-hydroxyibuprofen and 100 ng/mL for 3-hydroxyibuprofen. The applicability of the method was evaluated by the analysis of five real urine samples collected from different horses after drug administration. In view of the low limits of quantification, high selectivity, repeatability, and recovery, the procedure can be utilized for laboratory applications, including the control of ibuprofen abuse in equestrian sports for anti-doping purposes and drug/pharmaceutical mentality investigations.


Assuntos
Ibuprofeno/urina , Animais , Cromatografia Gasosa , Cavalos , Ibuprofeno/metabolismo , Extração Líquido-Líquido , Estrutura Molecular , Espectrometria de Massas em Tandem
10.
J Pharm Biomed Anal ; 152: 279-288, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29453024

RESUMO

A novel assay for the simultaneous determination of ibuprofen (IBU) and its four probable metabolites, 1-hydroxyibuprofen (1-OH IBU), 2-hydroxyibuprofen (2-OH IBU), 3-hydroxyibuprofen (3-OH IBU) and carboxyibuprofen (CBX IBU) in equine urine samples with the application of Gas Chromatography-Electron Ionization-Mass Spectrometry (GC-EI-MS) has been developed and elaborated. The new approach for sample preparation including minimizing matrix effects by the application of weak cation exchange solid-phase extraction together with strong cation exchange solid-phase extraction has been applied. The GC-EI-MS method was validated to demonstrate specificity, matrix effect, linearity, limit of detection (LOD) and quantification (LOQ), precision, trueness, carry-over and stability by using the matrix-matched quality control samples. Additionally, extraction yield was evaluated. The assay achieved the LOQ of 1.75 µg mL-1, 0.62 µg mL-1, 4.15 µg mL-1, 0.58 µg mL-1 and 4.04 µg mL-1 for IBU, 1-OH IBU, 2-OH IBU, 3-OH IBU and CBX IBU, respectively. The developed method has been successfully applied to the excretion study in horses, in which a single oral IBU dose was administered to twelve horses (mares and geldings) and equine urine samples were collected for 5 or 6 days after the drug administration. Data on the detection and determination of three IBU metabolites, 2-OH IBU, 3-OH IBU and CBX IBU in equine urine samples has been presented for the first time. The obtained results indicated the rapid excretion of IBU and its metabolites that were detectable only in the first day after the drug administration. IBU was mainly the most abundant compound detected in equine urine samples (with two exceptions in the case of samples collected from two horses, for which the highest instrumental responses were obtained for CBX IBU). The received results have indicated that two major IBU metabolites, CBX IBU and 2-OH IBU can be important markers for the IBU abuse in view of doping control in equestrian sports.


Assuntos
Ibuprofeno/metabolismo , Ibuprofeno/urina , Animais , Doping nos Esportes/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cavalos , Ibuprofeno/análogos & derivados , Limite de Detecção , Extração em Fase Sólida/métodos
11.
Talanta ; 179: 601-607, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310282

RESUMO

The use of polymer inclusion membranes (PIMs) as support of 1-octanol liquid membrane in electromembrane extraction (EME) procedure is proposed. Synthesis of PIMs were optimized to a composition of 29% (w/w) of cellulose triacetate as base polymer and 71% (w/w) of Aliquat®336 as cationic carrier. Flat PIMs of 25µm thickness and 6mm diameter were used. EME protocol was implemented for the simultaneous extraction of four non-steroidal anti-inflammatory drugs (NSAIDs) (salicylic acid, ketoprofen, naproxen and ibuprofen) and four highly polar acidic drugs (anthranilic acid, nicotinic acid, amoxicillin and hippuric acid). Posterior HPLC separation of the extracted analytes was developed with diode array detection. Recoveries in the 81-34% range were obtained. EME procedure was applied to human urine samples.


Assuntos
Anti-Inflamatórios não Esteroides/isolamento & purificação , Celulose/análogos & derivados , Técnicas Eletroquímicas , Compostos de Amônio Quaternário/química , Amoxicilina/isolamento & purificação , Amoxicilina/urina , Anti-Inflamatórios não Esteroides/urina , Celulose/química , Hipuratos/isolamento & purificação , Hipuratos/urina , Ibuprofeno/isolamento & purificação , Ibuprofeno/urina , Cetoprofeno/isolamento & purificação , Cetoprofeno/urina , Membranas Artificiais , Naproxeno/isolamento & purificação , Naproxeno/urina , Niacina/isolamento & purificação , Niacina/urina , Ácido Salicílico/isolamento & purificação , Ácido Salicílico/urina , ortoaminobenzoatos/isolamento & purificação , ortoaminobenzoatos/urina
12.
Anal Chim Acta ; 997: 67-79, 2018 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-29149996

RESUMO

In this work, a new, simple, rapid, and environmentally friendly method with a high sample clean-up capability termed as centrifugeless ultrasound-assisted dispersive micro solid-phase extraction coupled with salting-out ultrasound-assisted liquid-liquid microextraction based on solidification of a floating organic droplet followed by high performance liquid chromatography is introduced for the first time. In this method, the three non-steroidal anti-inflammatory drugs diclofenac, ibuprofen, and mefenamic acid are first extracted based on an effective nanoadsorbent named as the layered double hydroxide-carbon nanotube nanohybrid. The first step provides a rapid and convenient way to separate the adsorbent from the sample matrix by a syringe nanofilter without additional centrifugation. In the next step, which is based upon the salting-out effect, after emulsification in the presence of ultrasonic irradiation, the phase separation is simply achieved through the salting-out phenomenon, and the extracting solvent is suspended on top of the sample solution. Under the optimal experimental conditions including the initial pH value of 6.0, 8.0 mg of the nanohybrid, 3 min ultrasonic time, 100 µL elution solvent (first step), secondary pH value of 3.0, 60 µL of 1-undecanol, 60 s ultrasonic time, and flow rate of 3 mL min-1 (second step), good responses were obtained for diclofenac, ibuprofen, and mefenamic acid in the concentration ranges of 0.8-2000, 0.8-2500, and 0.5-2000 ng mL-1, respectively, with low limits of detection ranging from 0.1 to 0.2 ng mL-1. The intra-day and inter-day precisions for the target analytes at the three concentration levels were in the ranges of 6.1-7.8% and 6.3-8.1%, respectively. The proposed method was also successfully applied to the biological and waste water samples, and excellent recoveries were obtained in the range of 92.9-103.1% even when the matrix was complex.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Microextração em Fase Líquida/métodos , Microextração em Fase Sólida/métodos , Anti-Inflamatórios não Esteroides/sangue , Anti-Inflamatórios não Esteroides/urina , Diclofenaco/análise , Diclofenaco/sangue , Diclofenaco/urina , Humanos , Concentração de Íons de Hidrogênio , Hidróxidos/química , Ibuprofeno/sangue , Ibuprofeno/química , Ibuprofeno/urina , Limite de Detecção , Ácido Mefenâmico/sangue , Ácido Mefenâmico/química , Ácido Mefenâmico/urina , Nanotubos de Carbono/química , Solventes/química , Ondas Ultrassônicas , Águas Residuárias/química
13.
Talanta ; 167: 617-622, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28340769

RESUMO

The application domains of classic enzyme-linked ligand binding assay (ELBA) is relatively narrow due to the high cost and hardly available binding receptor. In here, we described for the first time the possibility of developing a new ELBA based on silica nanoparticles (nano-SiO2) to assess the ibuprofen in human urine. Nano-SiO2 with a large surface area was introduced as stationary phase to improve the analytical performance. In the experiment, a competitively binding procedure with human serum albumin (HSA) was performed between the ibuprofen presented in sample and horseradish peroxidase labeled ibuprofen (HRP-ibuprofen) subsequently added. After centrifugal separation, the HRP/ibuprofen/nano-SiO2 composite catalyzed the substrate solution (TMB/H2O2) with a color change from colorless to yellow for quantitative measurement via an ultraviolet spectrophotometer. As a validation of the new principle, the developed nano-ELBA method was applied in the determination of ibuprofen excreted in human urine with excellent performance. This detection range only depends on the solubility of ligand and sensitivity of UV spectrophotometer. Our results indicate that this new method demonstrated to be able to rapidly and adequately determine the concentration of components in biological samples and advocate its effectiveness for various applications.


Assuntos
Anti-Inflamatórios não Esteroides/urina , Ensaio de Imunoadsorção Enzimática/métodos , Peroxidase do Rábano Silvestre/metabolismo , Ibuprofeno/urina , Nanopartículas/química , Albumina Sérica Humana/metabolismo , Dióxido de Silício/química , Anti-Inflamatórios não Esteroides/metabolismo , Peroxidase do Rábano Silvestre/química , Humanos , Ibuprofeno/metabolismo , Nanopartículas/metabolismo , Albumina Sérica Humana/química , Dióxido de Silício/metabolismo
14.
Sci Rep ; 7: 39778, 2017 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-28051129

RESUMO

Metal-organic framework (MOF) membranes have received increasing attention as adsorbents, yet the defects in most membrane structures greatly thwart their capacity performance. In this work, we fabricated a novel ZnO/2-methylimidazole nanocomposite with multiple morphology by electrochemical method. The nanocomposite provided sufficient and strong anchorages for the zeolitic imidazolate frameworks-8 (ZIF-8) membrane. Thus, a crack-free and uniform MOF membrane with high performance was successfully obtained. In this case, 2-methylimidazole was believed to react with ZnO to form uniform ZIF nuclei, which induced and guided the growth of ZIF-8 membrane. The as-prepared ZIF-8 membrane had large surface area and good thermal stability. As expected, it displayed high adsorption capacity for acidic drugs (e.g., ibuprofen, ketoprofen and acetylsalicylic acid) as they could interact through hydrophobic, hydrogen bonding and π-π stacking interaction. Accordingly, by coupling with gas chromatography the ZIF-8 membrane was successfully applied to the real-time dynamic monitoring of ibuprofen in patient's urine.


Assuntos
Ibuprofeno/urina , Imidazóis/química , Estruturas Metalorgânicas/química , Nanocompostos/química , Zeolitas/química , Óxido de Zinco/química , Adsorção , Aspirina/química , Galvanoplastia , Voluntários Saudáveis , Humanos , Ibuprofeno/química , Cetoprofeno/química
15.
Electrophoresis ; 37(2): 274-81, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26530782

RESUMO

This study describes a method to determine nonsteroidal anti-inflammatory drugs (NSAIDs) in urine samples based on the use of single-drop microextraction (SDME) in a three-phase design as a preconcentration technique coupled in-line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 µg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27-fold for ketoprofen, 14-fold for diclofenac, 12-fold for ibuprofen, and 44-fold naproxen. Samples were analyzed applying the SDME-CE method and the obtained results presented satisfactory recovery values (82-115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment.


Assuntos
Anti-Inflamatórios não Esteroides/urina , Eletroforese Capilar/instrumentação , Microextração em Fase Líquida/instrumentação , Adulto , Anti-Inflamatórios não Esteroides/isolamento & purificação , Diclofenaco/isolamento & purificação , Diclofenaco/urina , Desenho de Equipamento , Humanos , Ibuprofeno/isolamento & purificação , Ibuprofeno/urina , Cetoprofeno/isolamento & purificação , Cetoprofeno/urina , Limite de Detecção , Naproxeno/isolamento & purificação , Naproxeno/urina , Urinálise/instrumentação
16.
Pharmacoepidemiol Drug Saf ; 25(4): 431-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26696520

RESUMO

PURPOSE: Although sales of prescribed and over-the-counter (OTC) medication are rising, little is known about individual drug intake. This study was aimed to obtain complementary information about drug intake. METHOD: Information on drug utilization was obtained in a female cohort for five different time points (TP): 36th week of pregnancy (n = 622), 7th perinatal week (n = 533), 3rd perinatal month (n = 340), and 1st perinatal (n = 534) and 3rd perinatal year (n = 324) by a validated urine screening method. RESULTS: Drugs were detected 807 times among all analyzed samples (n = 2353) with less drug intake for early TP compared with later TP (~24.4%, n = 152; ~33.8%, n = 180; ~23.2%, n = 79; ~42.5%, n = 227; and ~52.2%, n = 169). The diversity of drugs increased from 25 up to 40 different drugs for the investigated period. OTC drugs were detected most frequently reflected by the top three drugs: acetaminophen (~37%, n = 292), ibuprofen (~23%, n = 183), and xylometazoline (~12%, n = 98). Mainly guideline-orientated drug therapy was observed. However, contraindicated ibuprofen intake during third trimester urine samples (n = 26) and a repeated usage of acetaminophen and/or ibuprofen (n = 9), as well as xylometazoline (n = 7), reveal missing information about drug safety. CONCLUSION: Bio monitoring was applied for detection of drug intake revealing a lack of information about OTC products and their health risks. Hence, information about health risks for certain drugs and patient groups must be improved for and by pharmacists, to avoid (i) usage of contraindicated drugs and (ii) abuse of OTC drugs.


Assuntos
Medicamentos sem Prescrição/administração & dosagem , Guias de Prática Clínica como Assunto , Medicamentos sob Prescrição/administração & dosagem , Urinálise/métodos , Acetaminofen/administração & dosagem , Acetaminofen/urina , Contraindicações , Feminino , Humanos , Ibuprofeno/administração & dosagem , Ibuprofeno/urina , Imidazóis/administração & dosagem , Imidazóis/urina , Medicamentos sem Prescrição/análise , Período Pós-Parto , Gravidez , Medicamentos sob Prescrição/análise , Estudos Prospectivos , Fatores de Tempo
17.
J Chromatogr A ; 1393: 1-7, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-25840660

RESUMO

Polymer monolith microextraction (PMME) based on capillary monolithic column is an effective and useful technique to preconcentrate trace analytes from environmental and biological samples. Here, we report the fabrication of a novel aluminum terephthalate metal-organic framework (MIL-53(Al)) incorporated capillary monolithic column via in situ polymerization for the PMME of non-steroidal anti-inflammatory drugs (NSAIDs) (ketoprofen, fenbufen and ibuprofen) in water and urine samples. The fabricated MIL-53(Al) incorporated monolith was characterized by X-ray powder diffractometry, scanning electron microscopy, Fourier transform infrared spectrometry, and nitrogen adsorption experiment. The MIL-53(Al) incorporated monolith gave larger surface area than the neat polymer monolith. A 2-cm long MIL-53(Al) incorporated capillary monolith was applied for PMME coupled with high-performance liquid chromatography for the determination of the NSAIDs. Potential factors affecting the PMME were studied in detail. Under the optimized conditions, the developed method gave the enhancement factors of 46-51, the linear range of 0.40-200µgL(-1), the detection limits (S/N=3) of 0.12-0.24µgL(-1), and the quantification limits (S/N=10) of 0.40-0.85µgL(-1). The recoveries for spiked NSAIDs (20µgL(-1)) in water and urine samples were in the range of 77.3-104%. Besides, the MIL-53(Al) incorporated monolith was stable enough for 120 extraction cycles without significant loss of extraction efficiency. The developed method was successfully applied to the determination of NSAIDs in water and urine samples.


Assuntos
Anti-Inflamatórios não Esteroides/isolamento & purificação , Ibuprofeno/isolamento & purificação , Cetoprofeno/isolamento & purificação , Metacrilatos , Fenilbutiratos/isolamento & purificação , Ácidos Ftálicos , Extração em Fase Sólida/instrumentação , Adsorção , Alumínio , Anti-Inflamatórios não Esteroides/urina , Cromatografia Líquida de Alta Pressão/métodos , Ibuprofeno/urina , Cetoprofeno/urina , Limite de Detecção , Fenilbutiratos/urina , Sais , Extração em Fase Sólida/métodos , Água/química
18.
J Chromatogr A ; 1392: 28-36, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25795396

RESUMO

A new dendrimer-functionalized mesoporous silica material based on large-pore 3D cubic Korea Advanced Institute of Science and Technology-6 (KIT-6) was synthesized by the growing of dendritic branches inside the mesopores of aminopropyl functionalized KIT-6. Detailed physical characterizations using transmission electron microscopy, nitrogen adsorption-desorption measurements, Fourier transform infrared (FTIR) spectroscopy, and elemental analysis reveal that the multifunctional dendrimers have been grown successfully within the confined spaces of mesopores. Although the 3D ordered mesoporous architecture of KIT-6 was well preserved, there was a significant and continuous decrease in pore size, specific surface area (SBET) and pore volume when increasing dendrimer generation up to six. In order to get a compromise between the SBET, pore size and density of functionalities, the dendrimer-functionalized KIT-6 (DF-KIT-6) for generation 2 (SBET, 314.2 m(2) g(-1); pore size, 7.9 nm; carbon and nitrogen contents, 19.80% and 1.92%) was selected for solid phase extraction (SPE) applications. The DF-KIT-6 was then evaluated as a reversed-phase/anion-exchange mixed-mode sorbent for extraction of the selected acidic drugs (ketoprofen, KEP; naproxen, NAP; and ibuprofen, IBU), since the dendrimers contained both hydrocarbonaceous and amine functionalities. The effective parameters on extraction efficiency such as sample pH and volume, type and volume of eluent and wash solvents were optimized. Under the optimized experimental conditions, the DF-KIT-6 based SPE coupled with HPLC-UV method demonstrated good sensitivity (0.4-4.6 ng mL(-1) detection of limits) and linearity (R(2)>0.990 for 10-2000 ng mL(-1) of KEP and IBU, and 1-200 ng mL(-1) of NAP). The potential use of DF-KIT-6 sorbent for preconcentration and cleanup of acid drugs in human urine samples was also demonstrated. Satisfactory recoveries at two spiking levels (30 and 300 ng mL(-1) for KEP and IBU, 3 and 30 ng mL(-1) for NAP) were obtained in the range of 85.7-113.9% with RSD values below 9.3% (n=3).


Assuntos
Dendrímeros/química , Preparações Farmacêuticas/urina , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Adsorção , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Ibuprofeno/urina , Troca Iônica , Cetoprofeno/urina , Naproxeno/urina , Porosidade , Solventes , Espectroscopia de Infravermelho com Transformada de Fourier
19.
Water Res ; 68: 510-21, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25462757

RESUMO

This research advances the knowledge of ion-exchange of four non-steroidal anti-inflammatory drugs (NSAIDs) - diclofenac (DCF), ibuprofen (IBP), ketoprofen (KTP), and naproxen (NPX) - and one analgesic drug-paracetamol (PCM) - by strong-base anion exchange resin (AER) in synthetic ureolyzed urine. Freundlich, Langmuir, Dubinin-Astakhov, and Dubinin-Radushkevich isotherm models were fit to experimental equilibrium data using nonlinear least squares method. Favorable ion-exchange was observed for DCF, KTP, and NPX, whereas unfavorable ion-exchange was observed for IBP and PCM. The ion-exchange selectivity of the AER was enhanced by van der Waals interactions between the pharmaceutical and AER as well as the hydrophobicity of the pharmaceutical. For instance, the high selectivity of the AER for DCF was due to the combination of Coulombic interactions between quaternary ammonium functional group of resin and carboxylate functional group of DCF, van der Waals interactions between polystyrene resin matrix and benzene rings of DCF, and possibly hydrogen bonding between dimethylethanol amine functional group side chain and carboxylate and amine functional groups of DCF. Based on analysis of covariance, the presence of multiple pharmaceuticals did not have a significant effect on ion-exchange removal when the NSAIDs were combined in solution. The AER reached saturation of the pharmaceuticals in a continuous-flow column at varying bed volumes following a decreasing order of DCF > NPX ≈ KTP > IBP. Complete regeneration of the column was achieved using a 5% (m/m) NaCl, equal-volume water-methanol solution. Results from multiple treatment and regeneration cycles provide insight into the practical application of pharmaceutical ion-exchange in ureolyzed urine using AER.


Assuntos
Resinas de Troca Aniônica/química , Diclofenaco/química , Ibuprofeno/química , Cetoprofeno/química , Naproxeno/química , Acetaminofen/química , Acetaminofen/isolamento & purificação , Acetaminofen/urina , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/isolamento & purificação , Anti-Inflamatórios não Esteroides/urina , Química Farmacêutica/métodos , Diclofenaco/isolamento & purificação , Diclofenaco/urina , Humanos , Ligação de Hidrogênio , Ibuprofeno/isolamento & purificação , Ibuprofeno/urina , Troca Iônica , Cetoprofeno/isolamento & purificação , Cetoprofeno/urina , Cinética , Estrutura Molecular , Naproxeno/isolamento & purificação , Naproxeno/urina , Eletricidade Estática , Ureia/metabolismo , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/urina
20.
J AOAC Int ; 97(2): 415-20, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24830154

RESUMO

This paper describes a GC/MS method for the determination of ibuprofen in human plasma and urine. Ibuprofen and internal standard naproxen were extracted from plasma and urine by using a liquid-liquid extraction method. Derivatization was carried out using N-methyl-N-(trimethylsilyl) trifluoroacetamide. Calibration curves were linear over the concentration range of 0.05-5.0 and 0.1-10.0 microg/mL for plasma and urine, respectively. Intraday and interday precision (RSD) values for ibuprofen in plasma and urine were less than 6.31%, and accuracy (relative error) was better than 12.00%. The mean recovery of ibuprofen was 89.53% for plasma and 93.73% for urine. The LOD was 0.015 and 0.03 microg/mL and the LOQ was 0.05 and 0.1 microg/mL for plasma and urine, respectively. The method was successfully applied to blood samples from three healthy male volunteers who had been given an oral tablet of 600 mg ibuprofen.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Ibuprofeno/sangue , Ibuprofeno/urina , Adulto , Humanos , Extração Líquido-Líquido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...